PREPARING ROW
|
STA
|
118.180
|
|
|
REMOV CONC (PAV)
|
SY
|
17,053.000
|
|
|
REMOV CONC (RIPRAP)
|
SY
|
1,165.000
|
|
|
REMOV CONC (SAWCUT)
|
LF
|
1,567.000
|
|
|
REMOV CONC (RETAINING WALLS)
|
SY
|
39.000
|
|
|
REMOV CONC (WINGWALL)
|
CY
|
7.000
|
|
|
REMOV CONC (RAIL)
|
LF
|
961.000
|
|
|
REMOV CONC (FLUME)
|
SY
|
443.000
|
|
|
EXCAV (ROADWAY)
|
CY
|
37,515.000
|
|
|
EMBANK (FNL)(DC)(TY C)
|
CY
|
34,994.000
|
|
|
EMBANK (FNL)(DC)(TY C2)
|
CY
|
7,075.000
|
|
|
EMBANK (FNL)(DC)(TY E)(CSBE)
|
CY
|
756.000
|
|
|
COMPOST MANUF TOPSOIL (4")
|
SY
|
33,175.000
|
|
|
BLOCK SODDING
|
SY
|
25,019.000
|
|
|
STRAW OR HAY MULCH
|
SY
|
16,912.000
|
|
|
BROADCAST SEED (PERM_URBAN_CLAY)
|
SY
|
33,175.000
|
|
|
BROADCAST SEED (TEMP_WARM)
|
SY
|
225.000
|
|
|
BROADCAST SEED (TEMP_WARM_COOL)
|
SY
|
33,175.000
|
|
|
DRILL SEED (TEMP_WARM_COOL)
|
SY
|
4,471.000
|
|
|
FERTILIZER
|
AC
|
19.860
|
|
|
VEGETATIVE WATERING
|
TGL
|
2,383.000
|
|
|
LIME (COM OR QK)(SLURRY) OR QK(DRY)
|
TON
|
549.490
|
|
|
LIME TRT (EXIST MATL)(6")
|
SY
|
40,762.000
|
|
|
CEMENT
|
TON
|
285.000
|
|
|
CEMENT TRT (EXIST MATL)(6")
|
SY
|
21,172.000
|
|
|
CEM TRT(PLNT MX)(CL N)(TY E)(GR 4)(6")
|
SY
|
19,590.000
|
|
|
ASPHALT TRT BASE (GR 4)(PG 64)
|
TON
|
2,288.470
|
|
|
CONC PVMT (CRCP) (10")
|
SY
|
13,247.000
|
|
|
CONC PVMT (CRCP) (12")
|
SY
|
24,296.000
|
|
|
STRUCT EXCAV
|
CY
|
2,122.000
|
|
|
STRUCT EXCAV (BOX)
|
CY
|
5,755.000
|
|
|
STRUCT EXCAV (PIPE)
|
CY
|
2,581.000
|
|
|
CEM STABIL BKFL
|
CY
|
3,225.000
|
|
|
CEMENT STAB BACKFILL (INLET OR MH)
|
CY
|
268.000
|
|
|
TRENCH EXCAVATION PROTECTION
|
LF
|
5,933.000
|
|
|
TEMPORARY SPL SHORING
|
SF
|
19,291.000
|
|
|
DRILL SHAFT (18 IN)
|
LF
|
160.000
|
|
|
DRILL SHAFT (30 IN)
|
LF
|
6,873.000
|
|
|
DRILL SHAFT (36 IN)
|
LF
|
286.000
|
|
|
DRILL SHAFT (42 IN)
|
LF
|
150.000
|
|
|
DRILL SHAFT (54 IN)
|
LF
|
187.000
|
|
|
DRILL SHAFT (SIGN MTS) (42 IN)
|
LF
|
150.000
|
|
|
DRILL SHAFT (RDWY ILL POLE) (30 IN)
|
LF
|
104.000
|
|
|
SOUND WALL
|
SF
|
106,040.000
|
|
|
CL C CONC (ABUT)
|
CY
|
38.400
|
|
|
CL C CONC (ABUT)(EXTEND)
|
CY
|
36.200
|
|
|
CL C CONC (CAP)
|
CY
|
32.600
|
|
|
CL C CONC (COLUMN)
|
CY
|
26.200
|
|
|
CL C CONC (SIGN COLUMN)
|
CY
|
105.500
|
|
|
CL C CONC (SIGN FOOTING)
|
CY
|
39.200
|
|
|
REINF CONC SLAB
|
SF
|
4,763.000
|
|
|
REINF CONC SLAB (EXTEND SLAB)
|
SF
|
4,459.000
|
|
|
APPROACH SLAB
|
CY
|
52.400
|
|
|
RETAINING WALL (MSE)
|
SF
|
17,935.000
|
|
|
RETAINING WALL (CAST-IN-PLACE)
|
SF
|
714.000
|
|
|
PRESTR CONC GIRDER (TX46)
|
LF
|
1,282.080
|
|
|
RIPRAP (CONC)(4 IN)
|
CY
|
508.130
|
|
|
RIPRAP (CONC)(5 IN)
|
CY
|
210.000
|
|
|
RIPRAP (CONC)(CL B)
|
CY
|
2.800
|
|
|
RIPRAP (CONC) (CL B) (4 IN)
|
CY
|
261.800
|
|
|
RIPRAP (CONC)(FLUME)
|
CY
|
239.000
|
|
|
RIPRAP (MOW STRIP)(4 IN)
|
CY
|
302.000
|
|
|
BEDDING MATERIAL (3 IN)
|
CY
|
671.000
|
|
|
RAIL (TY SSTR)
|
LF
|
5,680.940
|
|
|
RAIL (TY PR11)
|
LF
|
354.670
|
|
|
SEALED EXPANSION JOINT (4 IN) (SEJ - M)
|
LF
|
59.000
|
|
|
CONC BOX CULV (3 FT X 2 FT)
|
LF
|
2,484.000
|
|
|
CONC BOX CULV (8 FT X 3 FT)
|
LF
|
2,155.000
|
|
|
CONC BOX CULV (8 FT X 7 FT)(EXTEND)
|
LF
|
153.000
|
|
|
CONC BOX CULV (8 FT X 8 FT)(EXTEND)
|
LF
|
25.000
|
|
|
RC PIPE (CL III)(18 IN)
|
LF
|
143.000
|
|
|
RC PIPE (CL III)(24 IN)
|
LF
|
2,012.000
|
|
|
RC PIPE (CL III)(30 IN)
|
LF
|
98.000
|
|
|
RC PIPE (CL III)(36 IN)
|
LF
|
75.000
|
|
|
RC PIPE (CL III)(42 IN)
|
LF
|
122.000
|
|
|
RC PIPE (CL V)(24 IN)
|
LF
|
46.000
|
|
|
JCTBOX(COMPL)(PJB)(3FTX3FT)
|
EA
|
4.000
|
|
|
JCTBOX(COMPL)(PJB)(4FTX4FT)
|
EA
|
1.000
|
|
|
INLET (COMPL)(POD)(FG)(3FTX3FT)
|
EA
|
4.000
|
|
|
JUNCT BOX (COMPL)(JB)(7FT X 7FT)(FTW)
|
EA
|
1.000
|
|
|
INLET (COMPL)(CURB)(TY C1)(NONE)(HOU)
|
EA
|
18.000
|
|
|
INLET (COMPL)(CURB)(TY C1)(LEFT)(HOU)
|
EA
|
4.000
|
|
|
INLET (COMPL)(CURB)(TY C1)(RIGHT)(HOU)
|
EA
|
7.000
|
|
|
INLET (COMPL)(CURB)(TY C1)(BOTH)(HOU)
|
EA
|
9.000
|
|
|
INLET (COMPL)(TY A)(HOU)
|
EA
|
1.000
|
|
|
INLET (COMPL)(TY AAD)(HOU)
|
EA
|
10.000
|
|
|
INLET (COMPL)(TY AZR)(HOU)
|
EA
|
2.000
|
|
|
MANH (COMPL)(TY A)(HOU)
|
EA
|
11.000
|
|
|
WINGWALL (PW - 1) (HW=13 FT)
|
EA
|
1.000
|
|
|
WINGWALL (PW - 2) (HW=16 FT)
|
EA
|
1.000
|
|
|
SET (TY II) (18 IN) (RCP) (3: 1) (C)
|
EA
|
1.000
|
|
|
SET (TY II) (24 IN) (RCP) (4: 1) (C)
|
EA
|
1.000
|
|
|
PRE-CAST TRENCH DRAIN (IN CONC PAVEMNT)
|
LF
|
120.000
|
|
|
ADJUSTING INLETS
|
EA
|
1.000
|
|
|
REMOV STR (INLET)
|
EA
|
9.000
|
|
|
REMOV STR (SET)
|
EA
|
3.000
|
|
|
REMOV STR (HEADWALL)
|
EA
|
1.000
|
|
|
REMOV STR (PIPE)
|
LF
|
286.000
|
|
|
REMOV STR (BOX CULVERT)
|
LF
|
71.000
|
|
|
REMOVE STR (RAIL)
|
LF
|
580.000
|
|
|
REMOV STR (RET WALL)
|
LF
|
607.000
|
|
|
MOBILIZATION
|
LS
|
1.000
|
|
|
BARRICADES, SIGNS AND TRAFFIC HANDLING
|
MO
|
25.000
|
|
|
PORTABLE CHANGEABLE MESSAGE SIGN
|
EA
|
6.000
|
|
|
TMA (STATIONARY)
|
DAY
|
48.000
|
|
|
TMA (MOBILE OPERATION)
|
DAY
|
116.000
|
|
|
ROCK FILTER DAMS (INSTALL) (TY 1)
|
LF
|
25.000
|
|
|
ROCK FILTER DAMS (INSTALL) (TY 3)
|
LF
|
100.000
|
|
|
ROCK FILTER DAMS (INSTALL) (TY 4)
|
LF
|
20.000
|
|
|
ROCK FILTER DAMS (REMOVE)
|
LF
|
145.000
|
|
|
CONSTRUCTION EXITS (INSTALL) (TY 1)
|
SY
|
738.000
|
|
|
CONSTRUCTION EXITS (REMOVE)
|
SY
|
738.000
|
|
|
SANDBAGS FOR EROSION CONTROL
|
EA
|
28.000
|
|
|
TEMP SEDMT CONT FENCE (INSTALL)
|
LF
|
11,759.000
|
|
|
TEMP SEDMT CONT FENCE (REMOVE)
|
LF
|
11,759.000
|
|
|
BIODEG EROSN CONT LOGS (INSTL) (8")
|
LF
|
300.000
|
|
|
BIODEG EROSN CONT LOGS (INSTL) (12")
|
LF
|
1,396.000
|
|
|
BIODEG EROSN CONT LOGS (REMOVE)
|
LF
|
1,696.000
|
|
|
CONSTRUCTING DETOURS
|
SY
|
1,592.000
|
|
|
PORT CTB (DES SOURCE)(SGL SLP)(TY 1)
|
LF
|
8,329.000
|
|
|
PORT CTB (DES SOURCE)(LOW PROF)(TY 1)
|
LF
|
6,240.000
|
|
|
PORT CTB (DES SOURCE)(LOW PROF)(TY 2)
|
LF
|
180.000
|
|
|
PORT CTB (MOVE)(SGL SLP)(TY 1)
|
LF
|
5,779.000
|
|
|
PORT CTB (MOVE)(LOW PROF)(TY 1)
|
LF
|
5,040.000
|
|
|
PORT CTB (MOVE)(LOW PROF)(TY 2)
|
LF
|
120.000
|
|
|
PORT CTB (STKPL)(SGL SLP)(TY 1)
|
LF
|
8,329.000
|
|
|
PORT CTB (REMOVE)(LOW PROF)(TY 1)
|
LF
|
6,240.000
|
|
|
PORT CTB (REMOVE)(LOW PROF)(TY 2)
|
LF
|
180.000
|
|
|
CONC CURB (MONO) (TY II)
|
LF
|
14,016.690
|
|
|
CONC SIDEWALKS (5")
|
SY
|
8,231.000
|
|
|
MTL W-BEAM GD FEN (TIM POST)
|
LF
|
450.000
|
|
|
MTL BEAM GD FEN TRANS (THRIE-BEAM)
|
EA
|
1.000
|
|
|
REMOVE METAL BEAM GUARD FENCE
|
LF
|
1,150.000
|
|
|
REMOVE TERMINAL ANCHOR SECTION
|
EA
|
2.000
|
|
|
GUARDRAIL END TREATMENT (INSTALL)
|
EA
|
2.000
|
|
|
GUARDRAIL END TREATMENT (REMOVE)
|
EA
|
7.000
|
|
|
CRASH CUSH ATTEN (MOVE & RESET)
|
EA
|
5.000
|
|
|
CRASH CUSH ATTEN (REMOVE)
|
EA
|
5.000
|
|
|
CRASH CUSH ATTEN (INSTL)(L)(N)(TL2)
|
EA
|
1.000
|
|
|
CRASH CUSH ATTEN (INSTL)(L)(N)(TL3)
|
EA
|
4.000
|
|
|
CRASH CUSH ATTEN (INSTL)(R)(N)(TL3)
|
EA
|
1.000
|
|
|
CCA (INSTL)(N)(TL3)(WORK ZONE)
|
EA
|
4.000
|
|
|
PIPE UNDERDRAINS (TY 6) (6")
|
LF
|
1,399.000
|
|
|
RELOCATE RD IL ASM (TRANS-BASE)
|
EA
|
7.000
|
|
|
REMOVE RD IL ASM (TRANS-BASE)
|
EA
|
6.000
|
|
|
IN RD IL (TY SA) 40T-8 (250W EQ) LED
|
EA
|
4.000
|
|
|
IN RD IL (TY AL) 40T-8 (250W EQ) LED
|
EA
|
6.000
|
|
|
IN RD IL (TY SA) 50T-12 (400W EQ) LED
|
EA
|
8.000
|
|
|
CONDT (PVC) (SCH 40) (2")
|
LF
|
720.000
|
|
|
CONDT (PVC) (SCH 80) (2")
|
LF
|
2,055.000
|
|
|
CONDT (PVC) (SCH 80) (2") (BORE)
|
LF
|
4,360.000
|
|
|
CONDT (PVC) (SCH 80) (3")
|
LF
|
50.000
|
|
|
CONDT (PVC) (SCH 80) (3") (BORE)
|
LF
|
6,120.000
|
|
|
CONDT (RM) (2")
|
LF
|
380.000
|
|
|
ITS MULTI-DUCT CND (PVC-80)(BORE)
|
LF
|
12,180.000
|
|
|
ELEC CONDR (NO.14) INSULATED
|
LF
|
6,710.000
|
|
|
ELEC CONDR (NO.12) BARE
|
LF
|
230.000
|
|
|
ELEC CONDR (NO.12) INSULATED
|
LF
|
460.000
|
|
|
ELEC CONDR (NO.8) BARE
|
LF
|
7,855.000
|
|
|
ELEC CONDR (NO.8) INSULATED
|
LF
|
15,910.000
|
|
|
ELEC CONDR (NO.6) BARE
|
LF
|
8,850.000
|
|
|
ELEC CONDR (NO.6) INSULATED
|
LF
|
4,425.000
|
|
|
ITS GND BOX(PCAST) TY 1 (243636)W/APRN
|
EA
|
14.000
|
|
|
REMOVE ITS GROUND BOX
|
EA
|
9.000
|
|
|
GROUND BOX TY A (122311)W/APRON
|
EA
|
8.000
|
|
|
GROUND BOX TY C (162911)W/APRON
|
EA
|
5.000
|
|
|
REMOVE GROUND BOX
|
EA
|
11.000
|
|
|
RELOCATE ELECTRICAL SERVICES
|
EA
|
1.000
|
|
|
REMOVE ELECTRICAL SERVICES
|
EA
|
2.000
|
|
|
ELC SRV TY A 240/480 060(NS)SS(E)SP(O)
|
EA
|
1.000
|
|
|
ELC SRV TY A 240/480 060(SS)SS(E)GC(O)
|
EA
|
2.000
|
|
|
ELC SRV TY A 240/480 060(SS)SS(E)SP(U)
|
EA
|
2.000
|
|
|
ALUMINUM SIGNS (TY G)
|
SF
|
30.000
|
|
|
ALUMINUM SIGNS (TY O)
|
SF
|
857.250
|
|
|
IN SM RD SN SUP&AM TY10BWG(1)SA(P)
|
EA
|
16.000
|
|
|
IN SM RD SN SUP&AM TY10BWG(1)SA(T)
|
EA
|
18.000
|
|
|
IN SM RD SN SUP&AM TY10BWG(1)SA(U)
|
EA
|
1.000
|
|
|
IN SM RD SN SUP&AM TYS80(1)SA(T)
|
EA
|
4.000
|
|
|
IN SM RD SN SUP&AM TYS80(2)SA(P-EXAL)
|
EA
|
1.000
|
|
|
REMOVE SM RD SN SUP&AM
|
EA
|
22.000
|
|
|
INSTALL LRSS (STRUCT STEEL)
|
LB
|
325.000
|
|
|
RELOCATE LRSA
|
EA
|
1.000
|
|
|
REMOVE LRSA
|
EA
|
5.000
|
|
|
INS OH SN SUP(35 FT CANT)(SPAN ONLY)
|
EA
|
1.000
|
|
|
INS OH SN SUP(40 FT CANT)(SPAN ONLY)
|
EA
|
3.000
|
|
|
REMOVE OVERHD SIGN SUP
|
EA
|
4.000
|
|
|
REMOVE OVERHD SIGN SUP (SIGN ONLY)
|
EA
|
2.000
|
|
|
INSTL DEL ASSM (D-SW)SZ 1(BRF)CTB
|
EA
|
35.000
|
|
|
INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2
|
EA
|
18.000
|
|
|
INSTL DEL ASSM (D-SY)SZ 1(BRF)CTB
|
EA
|
6.000
|
|
|
INSTL DEL ASSM (D-SY)SZ 1(BRF)GF2
|
EA
|
6.000
|
|
|
WK ZN PAV MRK REMOV (W)6"(BRK)
|
LF
|
9,041.000
|
|
|
WK ZN PAV MRK REMOV (W)6"(SLD)
|
LF
|
30,161.000
|
|
|
WK ZN PAV MRK REMOV (W)8"(SLD)
|
LF
|
1,331.000
|
|
|
WK ZN PAV MRK REMOV (W)6"(BKN W/MRKR)
|
LF
|
560.000
|
|
|
WK ZN PAV MRK REMOV (W)(ARROW)
|
EA
|
8.000
|
|
|
WK ZN PAV MRK REMOV (Y)6"(SLD)
|
LF
|
16,796.000
|
|
WK ZN PAV MRK SHT TERM (TAB)TY Y-2
|
EA
|
76.000
|
|
RE PM TY III (W)(6")(SLD)
|
LF
|
18,008.000
|
|
RE PM TY III (W)(6")(BRK)
|
LF
|
4,578.000
|
|
RE PM TY III (W)(8")(SLD)
|
LF
|
4,510.000
|
|
RE PM TY III (W)(12")(SLD)
|
LF
|
2,656.000
|
|
RE PM TY III (W)(12")(DOT)
|
LF
|
459.000
|
|
RE PM TY III (W)(24")(SLD)
|
LF
|
62.000
|
|
RE PM TY III (Y)(6")(SLD)
|
LF
|
12,568.000
|
|
RE PM TY III (BLK)(6")(SHADOW)
|
LF
|
3,411.000
|
|
|
PAVEMENT SLER (ARROW)
|
EA
|
8.000
|
|
|
PAVEMENT SLER (WORD)
|
EA
|
7.000
|
|
|
PAVEMENT SLER (DBL ARROW)
|
EA
|
1.000
|
|
|
PAVEMENT SLER (UTURN ARROW)
|
EA
|
2.000
|
|
PREFAB PM TY C (W)(ARROW)
|
EA
|
7.000
|
|
PREFAB PM TY C (W)(DBL ARROW)
|
EA
|
1.000
|
|
PREFAB PM TY C (W)(UTURN ARROW)
|
EA
|
2.000
|
|
PREFAB PM TY C (W)(WORD)
|
EA
|
9.000
|
|
REFL PAV MRKR TY II-C-R
|
EA
|
637.000
|
|
|
ELIM EXT PM & MRKS (6")
|
LF
|
12,506.000
|
|
|
ELIM EXT PM & MRKS (8")
|
LF
|
1,822.000
|
|
|
ELIM EXT PM & MRKS (12")
|
LF
|
302.000
|
|
|
ELIM EXT PM & MRKS (ARROW)
|
EA
|
2.000
|
|
|
ELIM EXT PM & MRKS (DBL ARROW)
|
EA
|
1.000
|
|
|
ELIM EXT PM & MRKS (WORD)
|
EA
|
2.000
|
|
|
PAV SURF PREP FOR MRK (6")
|
LF
|
37,375.000
|
|
|
PAV SURF PREP FOR MRK (8")
|
LF
|
4,510.000
|
|
|
PAV SURF PREP FOR MRK (12")
|
LF
|
3,115.000
|
|
|
PAV SURF PREP FOR MRK (24")
|
LF
|
62.000
|
|
|
PAV SURF PREP FOR MRK (ARROW)
|
EA
|
7.000
|
|
|
PAV SURF PREP FOR MRK (DBL ARROW)
|
EA
|
1.000
|
|
|
PAV SURF PREP FOR MRK (UTURN ARR)
|
EA
|
2.000
|
|
|
PAV SURF PREP FOR MRK (WORD)
|
EA
|
9.000
|
|
|
PAV SURF PREP FOR MRK (RPM)
|
EA
|
329.000
|
|
|
REMOVE LUMINAIRE POLE
|
EA
|
6.000
|
|
|
TREE REMOVAL (4" - 12" DIA)
|
EA
|
84.000
|
|
|
ITS POLE MNT CAB (TY 2)(CONF 2)
|
EA
|
1.000
|
|
|
ITS POLE (40 FT)(REM)
|
EA
|
1.000
|
|
|
FO CBL (96 SMF)
|
LF
|
12,060.000
|
|
|
INSTALL WRONG WAY DRIVER DETECTION SYS
|
EA
|
1.000
|
|
|
REMOVE WRONG WAY DRIVER DETECTION SYS
|
EA
|
1.000
|