PREPARING ROW
|
STA
|
6.000
|
|
|
REMOV CONC (MOWSTRIP)
|
LF
|
745.000
|
|
|
REMOV CONC (DRIVEWAYS)
|
SY
|
278.000
|
|
|
EXCAV (ROADWAY)
|
CY
|
9,309.000
|
|
|
EXCAV (CHANNEL)
|
CY
|
43.000
|
|
|
EMBANK (FNL)(DC)(TY A)
|
CY
|
24,618.000
|
|
|
BACKFILL (TY B)
|
STA
|
165.000
|
|
|
BLOCK SODDING
|
SY
|
1,500.000
|
|
|
BROADCAST SEED (PERM_RURAL_SAND)
|
SY
|
92,325.000
|
|
|
BROADCAST SEED (TEMP_WARM)
|
SY
|
46,167.000
|
|
|
BROADCAST SEED (TEMP_COOL)
|
SY
|
46,167.000
|
|
|
VEGETATIVE WATERING
|
TGL
|
1,560.000
|
|
|
CEMENT
|
TON
|
2,037.000
|
|
|
CEMENT TREAT (SUBGRADE) (8")
|
SY
|
139,826.000
|
|
|
PRIME COAT (MC-30)
|
GAL
|
33,928.000
|
|
|
D-GR HMA TY-B PG64-22
|
TON
|
29,863.000
|
|
|
D-GR HMA TY-B PG64-22 (LEVEL-UP)
|
TON
|
1,649.000
|
|
|
D-GR HMA TY-D PG70-28
|
TON
|
34,433.000
|
|
|
TACK COAT
|
GAL
|
18,816.000
|
|
|
FLEXIBLE PAVEMENT STRUCTURE REPAIR(6")
|
SY
|
9,038.000
|
|
|
PLANE ASPH CONC PAV(0" TO 2")
|
SY
|
14,538.000
|
|
|
TEMPORARY SPL SHORING
|
SF
|
559.000
|
|
|
CL B CONC (MISC)
|
CY
|
16.000
|
|
|
CL C CONC (MISC)
|
CY
|
3.000
|
|
|
RIPRAP (CONC)(4 IN)
|
CY
|
20.000
|
|
|
RIPRAP (CONC)(5 IN)
|
CY
|
10.000
|
|
|
RIPRAP (MOW STRIP)(4 IN)
|
CY
|
26.000
|
|
|
RIPRAP (STONE PROTECTION)(12 IN)
|
CY
|
173.000
|
|
|
RAIL (TY T631)
|
LF
|
33.000
|
|
|
CONC BOX CULV (3 FT X 2 FT)(EXTEND)
|
LF
|
32.000
|
|
|
CONC BOX CULV (4 FT X 2 FT)(EXTEND)
|
LF
|
28.000
|
|
|
CONC BOX CULV (4 FT X 3 FT)(EXTEND)
|
LF
|
8.000
|
|
|
CONC BOX CULV (5 FT X 3 FT)(EXTEND)
|
LF
|
13.000
|
|
|
CONC BOX CULV (5 FT X 5 FT)(EXTEND)
|
LF
|
30.000
|
|
|
CONC BOX CULV (6 FT X 2 FT)(EXTEND)
|
LF
|
18.000
|
|
|
RC PIPE (CL III)(18 IN)
|
LF
|
1,052.000
|
|
|
RC PIPE (CL III)(24 IN)
|
LF
|
130.000
|
|
|
RC PIPE (CL V)(18 IN)
|
LF
|
638.000
|
|
|
RC PIPE (CL V)(24 IN)
|
LF
|
105.000
|
|
|
WINGWALL (FW - 0) (HW=3 FT)
|
EA
|
7.000
|
|
|
WINGWALL (PW - 2) (HW=3 FT)
|
EA
|
4.000
|
|
|
WINGWALL (PW - 2) (HW=4 FT)
|
EA
|
4.000
|
|
|
WINGWALL (PW - 2) (HW=5 FT)
|
EA
|
2.000
|
|
|
WINGWALL (PW - 2) (HW=6 FT)
|
EA
|
1.000
|
|
|
WINGWALL (PW - 2) (HW=7 FT)
|
EA
|
1.000
|
|
|
WINGWALL (SW - 0) (HW=3 FT)
|
EA
|
1.000
|
|
|
SET (TY II) (18 IN) (RCP) (6: 1) (P)
|
EA
|
86.000
|
|
|
SET (TY II) (24 IN) (RCP) (6: 1) (P)
|
EA
|
14.000
|
|
|
CLEAN EXIST CULVERTS
|
EA
|
10.000
|
|
|
REMOV STR (SET)
|
EA
|
19.000
|
|
|
REMOV STR (WINGWALL)
|
EA
|
1.000
|
|
|
REMOV STR (PIPE)
|
LF
|
1,554.000
|
|
|
REMOVE STR (RAIL)
|
LF
|
33.000
|
|
|
MOBILIZATION
|
LS
|
1.000
|
|
|
BARRICADES, SIGNS AND TRAFFIC HANDLING
|
MO
|
19.000
|
|
|
TMA (STATIONARY)
|
DAY
|
375.000
|
|
|
TMA (MOBILE OPERATION)
|
DAY
|
47.000
|
|
|
ROCK FILTER DAMS (INSTALL) (TY 1)
|
LF
|
220.000
|
|
|
CONSTRUCTION EXITS (INSTALL) (TY 1)
|
SY
|
857.000
|
|
|
CONSTRUCTION EXITS (REMOVE)
|
SY
|
857.000
|
|
|
TEMP SEDMT CONT FENCE (INSTALL)
|
LF
|
16,540.000
|
|
|
TEMP SEDMT CONT FENCE (REMOVE)
|
LF
|
16,540.000
|
|
|
BIODEG EROSN CONT LOGS (INSTL) (12")
|
LF
|
7,220.000
|
|
|
BIODEG EROSN CONT LOGS (REMOVE)
|
LF
|
7,220.000
|
|
|
DRIVEWAYS (CONC)
|
SY
|
540.000
|
|
|
DRIVEWAYS (ACP)
|
SY
|
917.000
|
|
|
DRIVEWAYS (BASE)
|
SY
|
3,869.000
|
|
|
MILL RUMBLE STRIPS (ASPHALT) (SHLDR)
|
LF
|
102,775.000
|
|
|
MILL RUMBLE STRIPS (ASPH) (CENTERLINE)
|
LF
|
57,040.000
|
|
|
MTL W-BEAM GD FEN (TIM POST)
|
LF
|
200.000
|
|
|
REMOVE METAL BEAM GUARD FENCE
|
LF
|
475.000
|
|
|
GUARDRAIL END TREATMENT (INSTALL)
|
EA
|
2.000
|
|
|
GUARDRAIL END TREATMENT (REMOVE)
|
EA
|
4.000
|
|
|
WIRE FENCE (TY C)
|
LF
|
1,505.000
|
|
|
MAILBOX INSTALL-S (TWG-POST) TY 2
|
EA
|
317.000
|
|
|
MAILBOX INSTALL-M (TWW-POST) TY 4
|
EA
|
1.000
|
|
|
REPLACE EXISTING ALUMINUM SIGNS(TY A)
|
SF
|
602.000
|
|
|
IN SM RD SN SUP&AM TY10BWG(1)SA(T)
|
EA
|
4.000
|
|
|
IN SM RD SN SUP&AM TY10BWG(1)SA(U)
|
EA
|
2.000
|
|
|
IN SM RD SN SUP&AM TYS80(1)SA(U)
|
EA
|
2.000
|
|
|
IN SM RD SN SUP&AM TYTWT(1)WS(P)
|
EA
|
8.000
|
|
|
RELOCATE SM RD SN SUP&AM TY 10BWG
|
EA
|
6.000
|
|
|
RELOCATE SM RD SN SUP&AM TY S80
|
EA
|
2.000
|
|
|
RELOCATE SM RD SN SUP&AM TY TWT
|
EA
|
38.000
|
|
|
INSTL DEL ASSM (D-SW)SZ 1(WFLX)GND(BI)
|
EA
|
22.000
|
|
|
INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2(BI)
|
EA
|
130.000
|
|
|
INSTL OM ASSM (OM-2Z)(WFLX)SRFHH
|
EA
|
26.000
|
|
|
WK ZN PAV MRK NON-REMOV (W)6"(SLD)
|
LF
|
10,940.000
|
|
|
WK ZN PAV MRK NON-REMOV (Y)6"(BRK)
|
LF
|
560.000
|
|
|
WK ZN PAV MRK NON-REMOV (Y)6"(SLD)
|
LF
|
8,760.000
|
|
WK ZN PAV MRK SHT TERM (TAB)TY W
|
EA
|
5,860.000
|
|
WK ZN PAV MRK SHT TERM (TAB)TY Y-2
|
EA
|
5,792.000
|
|
REFL PAV MRK TY I (W)6"(DOT)(100MIL)
|
LF
|
430.000
|
|
REFL PAV MRK TY I (W)6"(LNDP)(100MIL)
|
LF
|
1,025.000
|
|
REFL PAV MRK TY I (W)8"(DOT)(100MIL)
|
LF
|
75.000
|
|
REFL PAV MRK TY I (W)8"(SLD)(100MIL)
|
LF
|
1,115.000
|
|
REFL PAV MRK TY I (W)24"(SLD)(100MIL)
|
LF
|
18.000
|
|
TY I HIGH PERF PM (W)6"(BRK)(100MIL)
|
LF
|
6,740.000
|
|
TY I HIGH PERF PM (W)6"(SLD)(100MIL)
|
LF
|
108,525.000
|
|
TY I HIGH PERF PM (Y)6"(SLD)(100MIL)
|
LF
|
118,895.000
|
|
PREFAB PM TY C (W)(ARROW)
|
EA
|
2.000
|
|
PREFAB PM TY C (W)(LN REDUCT ARROW)
|
EA
|
8.000
|
|
PREFAB PM TY C (W)(WORD)
|
EA
|
2.000
|
|
REFL PAV MRKR TY I-C
|
EA
|
395.000
|
|
REFL PAV MRKR TY II-A-A
|
EA
|
2,424.000
|
|
|
ELIM EXT PM & MRKS (6")
|
LF
|
4,300.000
|
|
|
PAV SURF PREP FOR MRK (6")
|
LF
|
4,300.000
|